Matches in DBpedia 2016-04 for { <http://wikidata.dbpedia.org/resource/Q6086400> ?p ?o }
Showing triples 1 to 46 of
46
with 100 triples per page.
- Q6086400 subject Q6061633.
- Q6086400 subject Q6151722.
- Q6086400 subject Q6226217.
- Q6086400 subject Q7320810.
- Q6086400 abstract "Isothermal microcalorimetry (IMC) is a laboratory method for real-time monitoring and dynamic analysis of chemical, physical and biological processes. Over a period of hours or days, IMC determines the onset, rate, extent and energetics of such processes for specimens in small ampoules (e.g. 3–20 ml) at a constant set temperature (ca. 15°C–150°C).IMC accomplishes this dynamic analysis by measuring and recording vs. elapsed time the net rate of heat flow (μJ/sec = μW) to or from the specimen ampoule, and the cumulative amount of heat (J) consumed or produced.IMC is a powerful and versatile analytical tool for four closely related reasons: All chemical and physical processes are either exothermic or endothermic—produce or consume heat. The rate of heat flow is proportional to the rate of the process taking place. IMC is sensitive enough to detect and follow either slow processes (reactions proceeding at a few % per year) in a few grams of material, or processes which generate minuscule amounts of heat (e.g. metabolism of a few thousand living cells). IMC instruments generally have a huge dynamic range—heat flows as low as ca. 1 μW and as high as ca. 50,000 μW can be measured by the same instrument.The IMC method of studying rates of processes is thus broadly applicable, provides real-time continuous data, and is sensitive. The measurement is simple to make, takes place unattended and is non-interfering (e.g. no fluorescent or radioactive markers are needed).However, there are two main caveats that must be heeded in use of IMC: Missed data: If externally prepared specimen ampoules are used, it takes ca. 40 minutes to slowly introduce an ampoule into the instrument without significant disturbance of the set temperature in the measurement module. Thus any processes taking place during this time are not monitored. Extraneous data: IMC records the aggregate net heat flow produced or consumed by all processes taking place within an ampoule. Therefore, in order to be sure what process or processes are producing the measured heat flow, great care must be taken in both experimental design and in the initial use of related chemical, physical and biologic assays.In general, possible applications of IMC are only limited by the imagination of the person who chooses to employ it as an analytical tool and the physical constraints of the method. Besides the two general limitations (main caveats) described above, these constraints include specimen and ampoule size, and the temperatures at which measurements can be made. IMC is generally best suited to evaluating processes which take place over hours or days. IMC has been used in an extremely wide range of applications, and many examples are discussed in this article, supported by references to published literature. Applications discussed range from measurement of slow oxidative degradation of polymers and instability of hazardous industrial chemicals to detection of bacteria in urine and evaluation of the effects of drugs on parasitic worms. The present emphasis in this article is applications of the latter type—biology and medicine.".
- Q6086400 thumbnail An_artists_rendition_of_an_isothermal_microcalorimetry_(IMC)_instrument_and_one_of_its_measurement_units.jpg?width=300.
- Q6086400 wikiPageExternalLink www.calmetrix.com.
- Q6086400 wikiPageExternalLink instruments.html.
- Q6086400 wikiPageExternalLink Microcalorimetry.htm.
- Q6086400 wikiPageExternalLink www.symcel.se.
- Q6086400 wikiPageExternalLink www.tainstruments.com.
- Q6086400 wikiPageWikiLink Q101026.
- Q6086400 wikiPageWikiLink Q12149006.
- Q6086400 wikiPageWikiLink Q12204.
- Q6086400 wikiPageWikiLink Q1540285.
- Q6086400 wikiPageWikiLink Q1637030.
- Q6086400 wikiPageWikiLink Q1754064.
- Q6086400 wikiPageWikiLink Q184204.
- Q6086400 wikiPageWikiLink Q189783.
- Q6086400 wikiPageWikiLink Q190143.
- Q6086400 wikiPageWikiLink Q193838.
- Q6086400 wikiPageWikiLink Q223143.
- Q6086400 wikiPageWikiLink Q223417.
- Q6086400 wikiPageWikiLink Q357519.
- Q6086400 wikiPageWikiLink Q37187.
- Q6086400 wikiPageWikiLink Q413478.
- Q6086400 wikiPageWikiLink Q477379.
- Q6086400 wikiPageWikiLink Q542419.
- Q6086400 wikiPageWikiLink Q552456.
- Q6086400 wikiPageWikiLink Q6061633.
- Q6086400 wikiPageWikiLink Q6151722.
- Q6086400 wikiPageWikiLink Q6226217.
- Q6086400 wikiPageWikiLink Q634314.
- Q6086400 wikiPageWikiLink Q643384.
- Q6086400 wikiPageWikiLink Q70906.
- Q6086400 wikiPageWikiLink Q715347.
- Q6086400 wikiPageWikiLink Q7320810.
- Q6086400 wikiPageWikiLink Q739016.
- Q6086400 wikiPageWikiLink Q762045.
- Q6086400 wikiPageWikiLink Q775480.
- Q6086400 wikiPageWikiLink Q804539.
- Q6086400 wikiPageWikiLink Q904041.
- Q6086400 wikiPageWikiLink Q904893.
- Q6086400 comment "Isothermal microcalorimetry (IMC) is a laboratory method for real-time monitoring and dynamic analysis of chemical, physical and biological processes. Over a period of hours or days, IMC determines the onset, rate, extent and energetics of such processes for specimens in small ampoules (e.g. 3–20 ml) at a constant set temperature (ca. 15°C–150°C).IMC accomplishes this dynamic analysis by measuring and recording vs.".
- Q6086400 label "Isothermal microcalorimetry".
- Q6086400 depiction An_artists_rendition_of_an_isothermal_microcalorimetry_(IMC)_instrument_and_one_of_its_measurement_units.jpg.