- Green_Power_Usage_Effectiveness abstract "Green Power Usage Effectiveness (GPUE) is a proposed measurement of both how much sustainable energy a computer data center uses, its carbon footprint per usable kilowatt hour (kWh) and how efficiently it uses its power; specifically, how much of the power is actually used by the computing equipment (in contrast to cooling and other overhead). It is an addition to the power usage effectiveness (PUE) definition and was first proposed by Greenqloud.The Green Grid has developed the Power Usage Effectiveness metric or PUE to measure a data centers' effectiveness of getting power to IT equipment. What the PUE tells in simple terms is how much extra energy is needed for each usable kWh for the IT equipment due to the power going into cooling, power distribution loss etc. and it’s a simple formula (in theory):PUE = Total Facility Power/IT Equipment PowerThe PUE can change depending on where measurements are made, when they are made and the timespan the measurements are made in.Data centers are subtracting factors from their PUE to lower it e.g. district heating. Some of the issues with PUE are being addressed with the PUEx definition.GPUE is a way to \"weigh\" the PUE to better see which data centers are truly green in the sense that they indirectly cause the least amount of CO2 to be emitted by their use of sustainable or unsustainable energy sources.This new metric GPUE or Green Power Usage Effectiveness is defined as:GPUE = G × PUEx (for inline comparison of data centers)or = G @ PUEx (a better display and for CO2 emission calculations)The \"G\" is the key factor here and it is a simple calculated value:G = Weighed sum of energy sources and their lifecycle KG CO2/KWhG =∑( %EnergySource × ( 1 + weight) )Adding 1 to the weight is to \"weigh\" (multiply) with the PUE to get a number that is comparable to PUE. The weights taken directly from the \"lifecycle CO2/kWh for electricity generation by power source\" table above we got from the 2008 Sovacool Study e.g. the weight for unscrubbed coal is e.g. 1.050 (kg of CO2/kWh) while hydroelectric river generation has a weight of 0.013. An unknown energy source or a \"mix\" will get the same as the maximum value which for now is the same as coal.Example:PUE 1.20, 50/50 Coal/HydroG = 0.5*(1+1.050) + 0.5*(1+0.013)G = 1.531, GPUEx = 1.84 or 1.531@1.20Kg CO2 per usable kWh = (G-1) × PUEx = 0.64 kg".
- Green_Power_Usage_Effectiveness wikiPageID "29469938".
- Green_Power_Usage_Effectiveness wikiPageLength "3702".
- Green_Power_Usage_Effectiveness wikiPageOutDegree "18".
- Green_Power_Usage_Effectiveness wikiPageRevisionID "619111357".
- Green_Power_Usage_Effectiveness wikiPageWikiLink Carbon_footprint.
- Green_Power_Usage_Effectiveness wikiPageWikiLink Category:Computer_benchmarks.
- Green_Power_Usage_Effectiveness wikiPageWikiLink Category:Computers_and_the_environment.
- Green_Power_Usage_Effectiveness wikiPageWikiLink Category:Electric_power.
- Green_Power_Usage_Effectiveness wikiPageWikiLink Category:Energy_conservation.
- Green_Power_Usage_Effectiveness wikiPageWikiLink Category:Sustainable_technologies.
- Green_Power_Usage_Effectiveness wikiPageWikiLink Data_center.
- Green_Power_Usage_Effectiveness wikiPageWikiLink Data_center_infrastructure_efficiency.
- Green_Power_Usage_Effectiveness wikiPageWikiLink GreenQloud.
- Green_Power_Usage_Effectiveness wikiPageWikiLink Green_computing.
- Green_Power_Usage_Effectiveness wikiPageWikiLink IT_energy_management.
- Green_Power_Usage_Effectiveness wikiPageWikiLink Kilowatt_hour.
- Green_Power_Usage_Effectiveness wikiPageWikiLink Life-cycle_greenhouse-gas_emissions_of_energy_sources.
- Green_Power_Usage_Effectiveness wikiPageWikiLink Performance_per_watt.
- Green_Power_Usage_Effectiveness wikiPageWikiLink Power_usage_effectiveness.
- Green_Power_Usage_Effectiveness wikiPageWikiLink Sustainable_energy.
- Green_Power_Usage_Effectiveness wikiPageWikiLink The_Green_Grid.
- Green_Power_Usage_Effectiveness wikiPageWikiLinkText "Green Power Usage Effectiveness".
- Green_Power_Usage_Effectiveness wikiPageUsesTemplate Template:Reflist.
- Green_Power_Usage_Effectiveness subject Category:Computer_benchmarks.
- Green_Power_Usage_Effectiveness subject Category:Computers_and_the_environment.
- Green_Power_Usage_Effectiveness subject Category:Electric_power.
- Green_Power_Usage_Effectiveness subject Category:Energy_conservation.
- Green_Power_Usage_Effectiveness subject Category:Sustainable_technologies.
- Green_Power_Usage_Effectiveness hypernym Measurement.
- Green_Power_Usage_Effectiveness type Company.
- Green_Power_Usage_Effectiveness type Comparison.
- Green_Power_Usage_Effectiveness type Computer.
- Green_Power_Usage_Effectiveness type Technology.
- Green_Power_Usage_Effectiveness comment "Green Power Usage Effectiveness (GPUE) is a proposed measurement of both how much sustainable energy a computer data center uses, its carbon footprint per usable kilowatt hour (kWh) and how efficiently it uses its power; specifically, how much of the power is actually used by the computing equipment (in contrast to cooling and other overhead).".
- Green_Power_Usage_Effectiveness label "Green Power Usage Effectiveness".
- Green_Power_Usage_Effectiveness sameAs Q5590525.
- Green_Power_Usage_Effectiveness sameAs m.0ds39cg.
- Green_Power_Usage_Effectiveness sameAs Q5590525.
- Green_Power_Usage_Effectiveness wasDerivedFrom Green_Power_Usage_Effectiveness?oldid=619111357.
- Green_Power_Usage_Effectiveness isPrimaryTopicOf Green_Power_Usage_Effectiveness.