Matches in DBpedia 2016-04 for { <http://dbpedia.org/resource/Cryogenic_current_comparator> ?p ?o }
Showing triples 1 to 43 of
43
with 100 triples per page.
- Cryogenic_current_comparator abstract "The cryogenic current comparator (CCC) is used in the electrical precision measurements to compare electric currents with highest accuracy. This device exceeds the accuracy of other current comparators around several orders of magnitude and is used in electrical metrology for highly precise comparative measurements of electric resistances or for the amplification and measurement of extremely small electric currents.The CCC principle goes back on Harvey and is based substantially on the properties of superconductors. CCCs make use of macroscopic quantum effects that occur in superconducting materials or circuits underneath their critical temperature of typically a few kelvins. The term “Cryogenic Current Comparator” stems from κρυος (Gr. frost, ice) and comparare (Lat. compare). The two quantum effects used in a CCC are the ideal diamagnetism of the superconductor, caused by the Meissner effect, and the macroscopic quantum interference of currents in a superconducting quantum sensor.For the comparison of two currents these are fed through two wires which are led through a superconducting tube. The Meissner effect induces a screening current on the inner surface of the tube, flowing opposite to and being exactly as large as the sum of the currents inside the tube. Thus, this shielding current exactly cancels the magnetic field inside the tube produced by the currents in the wires. The screening current flows back across the outer surface of the tube, giving rise to a magnetic field in the room outside of the tube. This field is detected by a highly sensitive magnetometer, acting as a null detector. The signal of this null detector thus is a measure for the equality of the currents; in particular it is zero if the two currents are of exactly equal magnitude. The important and crucial point characterizing the CCC is the fact that the magnitude of the screening current and its distribution on the surface of the superconducting screen are independent of the position and the path of the wires inside the tube.Typical for a CCC is the use of a SQUID magnetometer as null detector for the magnetic field (SQUID = Superconducting Quantum Interference Device). These are capable of detecting extremely small changes of the magnetic field corresponding to fractions of the magnetic flux quantum = h/2e ≈ 2×10−15 V·s (h is Planck's constant and e the elementary charge). The function principle of a SQUID is based on macroscopic quantum interferences of electric currents, arising in superconducting circuits (loops) with tunnel junctions.Resistance bridges based on CCCs are used for the comparison of electrical resistances, in particular if highest-precision measurements are required, as there is the traceability of the resistance unit to the quantum Hall effect (QHE). In this way, measurements connecting standard resistors ranging within 1 ohm up to 10 kΩ to a QHE resistor of 12.9 kΩ are performed at several national institutes of metrology as, for instance, the National Institute of Standards and Technology (NIST, USA) or the Physikalisch-Technische Bundesanstalt (PTB, D). Here, electrical resistance comparisons using CCCs are accomplished with relative measurement uncertainties of only about 10−9.".
- Cryogenic_current_comparator wikiPageExternalLink www.nist.gov.
- Cryogenic_current_comparator wikiPageExternalLink www.ptb.de.
- Cryogenic_current_comparator wikiPageExternalLink _ccchin_en.htm.
- Cryogenic_current_comparator wikiPageExternalLink _E-quantenhalleffekt.htm.
- Cryogenic_current_comparator wikiPageID "7982399".
- Cryogenic_current_comparator wikiPageLength "4292".
- Cryogenic_current_comparator wikiPageOutDegree "21".
- Cryogenic_current_comparator wikiPageRevisionID "593881922".
- Cryogenic_current_comparator wikiPageWikiLink Category:Electronic_test_equipment.
- Cryogenic_current_comparator wikiPageWikiLink Critical_point_(thermodynamics).
- Cryogenic_current_comparator wikiPageWikiLink Diamagnetism.
- Cryogenic_current_comparator wikiPageWikiLink Electric_current.
- Cryogenic_current_comparator wikiPageWikiLink Electrical_resistance_and_conductance.
- Cryogenic_current_comparator wikiPageWikiLink Elementary_charge.
- Cryogenic_current_comparator wikiPageWikiLink Greek_language.
- Cryogenic_current_comparator wikiPageWikiLink Kelvin.
- Cryogenic_current_comparator wikiPageWikiLink Latin.
- Cryogenic_current_comparator wikiPageWikiLink Magnetic_field.
- Cryogenic_current_comparator wikiPageWikiLink Magnetic_flux_quantum.
- Cryogenic_current_comparator wikiPageWikiLink Magnetometer.
- Cryogenic_current_comparator wikiPageWikiLink Measurement_uncertainty.
- Cryogenic_current_comparator wikiPageWikiLink Meissner_effect.
- Cryogenic_current_comparator wikiPageWikiLink Metrology.
- Cryogenic_current_comparator wikiPageWikiLink Ohm.
- Cryogenic_current_comparator wikiPageWikiLink Planck_constant.
- Cryogenic_current_comparator wikiPageWikiLink Quantum_Hall_effect.
- Cryogenic_current_comparator wikiPageWikiLink SQUID.
- Cryogenic_current_comparator wikiPageWikiLink Superconductivity.
- Cryogenic_current_comparator wikiPageWikiLink Traceability.
- Cryogenic_current_comparator wikiPageWikiLinkText "Cryogenic current comparator".
- Cryogenic_current_comparator wikiPageUsesTemplate Template:Reflist.
- Cryogenic_current_comparator subject Category:Electronic_test_equipment.
- Cryogenic_current_comparator type Instrument.
- Cryogenic_current_comparator type Instrument.
- Cryogenic_current_comparator comment "The cryogenic current comparator (CCC) is used in the electrical precision measurements to compare electric currents with highest accuracy.".
- Cryogenic_current_comparator label "Cryogenic current comparator".
- Cryogenic_current_comparator sameAs Q1790359.
- Cryogenic_current_comparator sameAs Kryostromkomparator.
- Cryogenic_current_comparator sameAs m.026mb2l.
- Cryogenic_current_comparator sameAs Q1790359.
- Cryogenic_current_comparator wasDerivedFrom Cryogenic_current_comparator?oldid=593881922.
- Cryogenic_current_comparator isPrimaryTopicOf Cryogenic_current_comparator.