Matches in DBpedia 2016-04 for { <http://wikidata.dbpedia.org/resource/Q906601> ?p ?o }
Showing triples 1 to 53 of
53
with 100 triples per page.
- Q906601 subject Q20978590.
- Q906601 subject Q8611186.
- Q906601 abstract "The Sensitive High Resolution Ion Microprobe (SHRIMP) is a large-diameter, double-focusing secondary ion mass spectrometer (SIMS) sector instrument produced by Australian Scientific Instruments in Canberra, Australia. Like other SIMS instruments, the SHRIMP microprobe bombards a sample under vacuum with a beam of primary ions that sputters secondary ions that are focused, filtered, and measured according to their energy and mass.The SHRIMP is primarily used for geological and geochemical applications. It can measure the isotopic and elemental abundances in minerals at a 30 micrometre-scale and is therefore well-suited for the analysis of complex minerals, as often found in metamorphic terrains, some igneous rocks, and for relatively rapid analysis of statistical valid sets of detrital minerals from sedimentary rocks. The most common application of the instrument is in uranium-thorium-lead geochronology, although the SHRIMP can be used to measure some other isotopic and elemental abundances.".
- Q906601 thumbnail SHRIMP_diagram.svg?width=300.
- Q906601 wikiPageExternalLink shrimp.anu.edu.au.
- Q906601 wikiPageExternalLink www.asi-pl.com.
- Q906601 wikiPageWikiLink Q104460.
- Q906601 wikiPageWikiLink Q1098.
- Q906601 wikiPageWikiLink Q1115.
- Q906601 wikiPageWikiLink Q1119.
- Q906601 wikiPageWikiLink Q1145497.
- Q906601 wikiPageWikiLink Q11573.
- Q906601 wikiPageWikiLink Q1266441.
- Q906601 wikiPageWikiLink Q127990.
- Q906601 wikiPageWikiLink Q1451086.
- Q906601 wikiPageWikiLink Q1507383.
- Q906601 wikiPageWikiLink Q1571347.
- Q906601 wikiPageWikiLink Q16018722.
- Q906601 wikiPageWikiLink Q172137.
- Q906601 wikiPageWikiLink Q178397.
- Q906601 wikiPageWikiLink Q178928.
- Q906601 wikiPageWikiLink Q1930710.
- Q906601 wikiPageWikiLink Q20978590.
- Q906601 wikiPageWikiLink Q213891.
- Q906601 wikiPageWikiLink Q214689.
- Q906601 wikiPageWikiLink Q2365355.
- Q906601 wikiPageWikiLink Q25276.
- Q906601 wikiPageWikiLink Q2594794.
- Q906601 wikiPageWikiLink Q3114.
- Q906601 wikiPageWikiLink Q3148743.
- Q906601 wikiPageWikiLink Q338146.
- Q906601 wikiPageWikiLink Q36496.
- Q906601 wikiPageWikiLink Q3937037.
- Q906601 wikiPageWikiLink Q42045.
- Q906601 wikiPageWikiLink Q4274076.
- Q906601 wikiPageWikiLink Q4571428.
- Q906601 wikiPageWikiLink Q47069.
- Q906601 wikiPageWikiLink Q5358555.
- Q906601 wikiPageWikiLink Q556046.
- Q906601 wikiPageWikiLink Q62100.
- Q906601 wikiPageWikiLink Q682.
- Q906601 wikiPageWikiLink Q708.
- Q906601 wikiPageWikiLink Q7085581.
- Q906601 wikiPageWikiLink Q716.
- Q906601 wikiPageWikiLink Q744.
- Q906601 wikiPageWikiLink Q8007032.
- Q906601 wikiPageWikiLink Q8611186.
- Q906601 wikiPageWikiLink Q898444.
- Q906601 wikiPageWikiLink Q902750.
- Q906601 wikiPageWikiLink Q906601.
- Q906601 comment "The Sensitive High Resolution Ion Microprobe (SHRIMP) is a large-diameter, double-focusing secondary ion mass spectrometer (SIMS) sector instrument produced by Australian Scientific Instruments in Canberra, Australia.".
- Q906601 label "Sensitive high-resolution ion microprobe".
- Q906601 depiction SHRIMP_diagram.svg.