- Q17056402 abstract "Infrared open-path gas detectors send out a beam of infrared light, detecting gas anywhere along the path of the beam. This linear 'sensor' is typically a few metres up to a few hundred metres in length. Open-path detectors can be contrasted with Infrared point sensors.They are widely used in the petroleum and petrochemical industries, mostly to achieve very rapid gas leak detection for flammable gases at concentrations comparable to the lower flammable limit (typically a few percent by volume). They are also used, but so far to a lesser extent, in other industries where flammable concentrations can occur, such as in coal mining and water treatment. In principle the technique can also be used to detect toxic gases, for instance hydrogen sulfide, at the necessary parts-per-million concentrations, but the technical difficulties involved have so far prevented widespread adoption for toxic gases.Usually, there are separate transmitter and receiver units at either end of a straight beam path. Alternatively, the source and receiver are combined, and the beam bounced off a retroreflector at the far end of the measurement path. For portable use, detectors have also been made which use the natural albedo of surrounding objects in place of the retroreflector. The presence of a chosen gas (or class of gases) is detected from its absorption of a suitable infrared wavelength in the beam. Rain, fog etc. in the measurement path can also reduce the strength of the received signal, so it is usual to make a simultaneous measurement at one or more reference wavelengths. The quantity of gas intercepted by the beam is then inferred from the ratio of the signal losses at the measurement and reference wavelengths. The calculation is typically carried out by a microprocessor which also carries out various checks to validate the measurement and prevent false alarms.The measured quantity is the sum of all the gas along the path of the beam, sometimes termed the path-integral concentration of the gas. Thus the measurement has a natural bias (desirable in many applications) towards the total size of an unintentional gas release, rather than the concentration of the gas that has reached any particular point. Whereas the natural units of measurement for an Infrared point sensor are parts-per-million (ppm) or the percentage of the lower flammable limit (%LFL), the natural units of measurement for an open path detector are ppm.metres (ppmm) or LFL.metres (LFLm). For instance, the fire and gas safety system on an offshore platform in the North Sea typically has detectors set to a full-scale reading of 5LFLm, with low and high alarms triggered at 1LFLm and 3LFLm respectively.".
- Q17056402 wikiPageExternalLink fgdetect.htm.
- Q17056402 wikiPageWikiLink Q101038.
- Q17056402 wikiPageWikiLink Q1058719.
- Q17056402 wikiPageWikiLink Q1132942.
- Q17056402 wikiPageWikiLink Q11388.
- Q17056402 wikiPageWikiLink Q1151304.
- Q17056402 wikiPageWikiLink Q1249999.
- Q17056402 wikiPageWikiLink Q12880211.
- Q17056402 wikiPageWikiLink Q1303258.
- Q17056402 wikiPageWikiLink Q13405580.
- Q17056402 wikiPageWikiLink Q1364904.
- Q17056402 wikiPageWikiLink Q1365258.
- Q17056402 wikiPageWikiLink Q1422588.
- Q17056402 wikiPageWikiLink Q170474.
- Q17056402 wikiPageWikiLink Q170591.
- Q17056402 wikiPageWikiLink Q173142.
- Q17056402 wikiPageWikiLink Q173582.
- Q17056402 wikiPageWikiLink Q175943.
- Q17056402 wikiPageWikiLink Q188463.
- Q17056402 wikiPageWikiLink Q193788.
- Q17056402 wikiPageWikiLink Q1967557.
- Q17056402 wikiPageWikiLink Q1998660.
- Q17056402 wikiPageWikiLink Q21069421.
- Q17056402 wikiPageWikiLink Q212111.
- Q17056402 wikiPageWikiLink Q214881.
- Q17056402 wikiPageWikiLink Q217351.
- Q17056402 wikiPageWikiLink Q254634.
- Q17056402 wikiPageWikiLink Q2601129.
- Q17056402 wikiPageWikiLink Q2718101.
- Q17056402 wikiPageWikiLink Q274160.
- Q17056402 wikiPageWikiLink Q2835.
- Q17056402 wikiPageWikiLink Q2890543.
- Q17056402 wikiPageWikiLink Q321098.
- Q17056402 wikiPageWikiLink Q3457898.
- Q17056402 wikiPageWikiLink Q37129.
- Q17056402 wikiPageWikiLink Q4103352.
- Q17056402 wikiPageWikiLink Q411436.
- Q17056402 wikiPageWikiLink Q43648.
- Q17056402 wikiPageWikiLink Q47616.
- Q17056402 wikiPageWikiLink Q4921139.
- Q17056402 wikiPageWikiLink Q5297.
- Q17056402 wikiPageWikiLink Q5322.
- Q17056402 wikiPageWikiLink Q5893986.
- Q17056402 wikiPageWikiLink Q6031505.
- Q17056402 wikiPageWikiLink Q605908.
- Q17056402 wikiPageWikiLink Q6434802.
- Q17056402 wikiPageWikiLink Q6814358.
- Q17056402 wikiPageWikiLink Q689880.
- Q17056402 wikiPageWikiLink Q690265.
- Q17056402 wikiPageWikiLink Q7013213.
- Q17056402 wikiPageWikiLink Q7098848.
- Q17056402 wikiPageWikiLink Q7153785.
- Q17056402 wikiPageWikiLink Q7167091.
- Q17056402 wikiPageWikiLink Q7316011.
- Q17056402 wikiPageWikiLink Q7465957.
- Q17056402 wikiPageWikiLink Q757528.
- Q17056402 wikiPageWikiLink Q8459627.
- Q17056402 wikiPageWikiLink Q8481411.
- Q17056402 wikiPageWikiLink Q862571.
- Q17056402 wikiPageWikiLink Q8692664.
- Q17056402 wikiPageWikiLink Q8693631.
- Q17056402 wikiPageWikiLink Q8696480.
- Q17056402 wikiPageWikiLink Q8760005.
- Q17056402 wikiPageWikiLink Q897136.
- Q17056402 wikiPageWikiLink Q900121.
- Q17056402 wikiPageWikiLink Q902086.
- Q17056402 wikiPageWikiLink Q902880.
- Q17056402 wikiPageWikiLink Q909168.
- Q17056402 wikiPageWikiLink Q922672.
- Q17056402 comment "Infrared open-path gas detectors send out a beam of infrared light, detecting gas anywhere along the path of the beam. This linear 'sensor' is typically a few metres up to a few hundred metres in length.".
- Q17056402 label "Infrared open-path detector".