- Esophogeal_doppler abstract "In medicine, Esophageal Doppler or Oesophageal Doppler uses a probe inserted into the esophagus through the nose or mouth to measure blood velocity in the descending aorta. From the probe tip, a beam of continuous wave ultrasound is directed through the esophageal wall into the aorta and reflects off the moving blood back to the probe; the Doppler effect is used to measure the velocity of the blood.In an Esophageal Doppler Monitor (EDM) or Oesophageal Doppler Monitor (ODM), during the time the aortic valve is open (ejection time), the average aortic blood velocity is calculated. The product of average velocity and ejection time gives the stroke distance (how far the blood travels in each heart cycle). An estimate of the aortic cross-sectional area is calculated from a function of physiological parameters (e.g., age, weight, and height). The product of stroke distance and cross-section area gives stroke volume (how much blood was ejected from a heartbeat into the arteries). The heart rate (HR) can be calculated from the time difference between the current peak velocity and the previous one. Cardiac output (CO) is the product of stroke volume and heart rate. Although CO is available beat by beat, it is usually averaged over a number of beats (typically 5) to reduce the variation in displayed value.".
- Esophogeal_doppler wikiPageID "48615358".
- Esophogeal_doppler wikiPageLength "1756".
- Esophogeal_doppler wikiPageOutDegree "17".
- Esophogeal_doppler wikiPageRevisionID "692983120".
- Esophogeal_doppler wikiPageWikiLink Aorta.
- Esophogeal_doppler wikiPageWikiLink Aortic_valve.
- Esophogeal_doppler wikiPageWikiLink Artery.
- Esophogeal_doppler wikiPageWikiLink Blood.
- Esophogeal_doppler wikiPageWikiLink Cardiac_output.
- Esophogeal_doppler wikiPageWikiLink Category:Intensive_care_medicine.
- Esophogeal_doppler wikiPageWikiLink Category:Medical_equipment.
- Esophogeal_doppler wikiPageWikiLink Continuous_wave.
- Esophogeal_doppler wikiPageWikiLink Descending_aorta.
- Esophogeal_doppler wikiPageWikiLink Doppler_effect.
- Esophogeal_doppler wikiPageWikiLink Esophagus.
- Esophogeal_doppler wikiPageWikiLink Medicine.
- Esophogeal_doppler wikiPageWikiLink Mouth.
- Esophogeal_doppler wikiPageWikiLink Nose.
- Esophogeal_doppler wikiPageWikiLink Physiology.
- Esophogeal_doppler wikiPageWikiLink Pulse.
- Esophogeal_doppler wikiPageWikiLink Ultrasound.
- Esophogeal_doppler wikiPageWikiLinkText "esophogeal doppler".
- Esophogeal_doppler wikiPageWikiLinkText "oesophageal Doppler".
- Esophogeal_doppler wikiPageUsesTemplate Template:Expert-subject.
- Esophogeal_doppler wikiPageUsesTemplate Template:Multiple_issues.
- Esophogeal_doppler wikiPageUsesTemplate Template:Reflist.
- Esophogeal_doppler wikiPageUsesTemplate Template:Unreferenced.
- Esophogeal_doppler subject Category:Intensive_care_medicine.
- Esophogeal_doppler subject Category:Medical_equipment.
- Esophogeal_doppler comment "In medicine, Esophageal Doppler or Oesophageal Doppler uses a probe inserted into the esophagus through the nose or mouth to measure blood velocity in the descending aorta.".
- Esophogeal_doppler label "Esophogeal doppler".
- Esophogeal_doppler wasDerivedFrom Esophogeal_doppler?oldid=692983120.
- Esophogeal_doppler isPrimaryTopicOf Esophogeal_doppler.