- Clitoral_photoplethysmograph abstract "Clitoral photoplethysmography uses a direct current signal to measure clitoral blood volume (CBV). A clitoral photoplethysmograph is a small clear acrylic device that contains a light source, and a light detector. The light source illuminates the capillary bed of the clitoral tissue and the blood circulating within it. As clitoral engorgement increases, more light is reflected into the photosensitive cell of the device. The clitoral photoplethysmograph is placed by the participant between the labia minora; the light detector is oriented toward the clitoris. It can be attached to a vaginal photoplethysmograph so that both CBV and vaginal pulse amplitude (VPA) can be measured simultaneously. Gerritsen found clitoral photoplethysmography to be a valid and sensitive tool for measuring female genital response. In contrast to vaginal photoplethysmography, clitoral photoplethysmographs are sensitive to the inhibition of sexual response. The authors suggest that clitoral photoplethysmography is particularly informative for examining sexual inhibition.".
- Clitoral_photoplethysmograph wikiPageExternalLink lab-equipment.
- Clitoral_photoplethysmograph wikiPageID "35416894".
- Clitoral_photoplethysmograph wikiPageLength "1817".
- Clitoral_photoplethysmograph wikiPageOutDegree "13".
- Clitoral_photoplethysmograph wikiPageRevisionID "687178537".
- Clitoral_photoplethysmograph wikiPageWikiLink Capillary.
- Clitoral_photoplethysmograph wikiPageWikiLink Category:Female_genital_procedures.
- Clitoral_photoplethysmograph wikiPageWikiLink Category:Medical_testing_equipment.
- Clitoral_photoplethysmograph wikiPageWikiLink Category:Sexology.
- Clitoral_photoplethysmograph wikiPageWikiLink Clitoris.
- Clitoral_photoplethysmograph wikiPageWikiLink Construct_validity.
- Clitoral_photoplethysmograph wikiPageWikiLink Direct_current.
- Clitoral_photoplethysmograph wikiPageWikiLink Labia_minora.
- Clitoral_photoplethysmograph wikiPageWikiLink Labial_thermistor_clip.
- Clitoral_photoplethysmograph wikiPageWikiLink Penile_plethysmograph.
- Clitoral_photoplethysmograph wikiPageWikiLink Vaginal_photoplethysmograph.
- Clitoral_photoplethysmograph wikiPageWikiLinkText "Clitoral photoplethysmograph".
- Clitoral_photoplethysmograph wikiPageUsesTemplate Template:Reflist.
- Clitoral_photoplethysmograph subject Category:Female_genital_procedures.
- Clitoral_photoplethysmograph subject Category:Medical_testing_equipment.
- Clitoral_photoplethysmograph subject Category:Sexology.
- Clitoral_photoplethysmograph comment "Clitoral photoplethysmography uses a direct current signal to measure clitoral blood volume (CBV). A clitoral photoplethysmograph is a small clear acrylic device that contains a light source, and a light detector. The light source illuminates the capillary bed of the clitoral tissue and the blood circulating within it. As clitoral engorgement increases, more light is reflected into the photosensitive cell of the device.".
- Clitoral_photoplethysmograph label "Clitoral photoplethysmograph".
- Clitoral_photoplethysmograph sameAs Q17001407.
- Clitoral_photoplethysmograph sameAs m.0zdsgvg.
- Clitoral_photoplethysmograph sameAs Q17001407.
- Clitoral_photoplethysmograph wasDerivedFrom Clitoral_photoplethysmograph?oldid=687178537.
- Clitoral_photoplethysmograph isPrimaryTopicOf Clitoral_photoplethysmograph.