- Correlated_double_sampling abstract "Correlated double sampling (CDS) is a method to measure electrical values such as voltages or currents that allows removing an undesired offset. It is used often when measuring sensor outputs. The output of the sensor is measured twice: once in a known condition and once in an unknown condition. The value measured from the known condition is then subtracted from the unknown condition to generate a value with a known relation to the physical quantity being measured.This is commonly used in switched capacitor operational amplifiers to effectively double the gain of the charge sharing opamp, while adding an extra phase.When used in imagers, correlated double sampling is a noise reduction technique in which the Reference Voltage of the pixel (i.e., the pixel’s voltage after it is reset) is removed from the Signal Voltage of the pixel (i.e., the pixel’s voltage at the end of integration) at the end of each integration period.".
- Correlated_double_sampling wikiPageID "20153971".
- Correlated_double_sampling wikiPageLength "1118".
- Correlated_double_sampling wikiPageOutDegree "6".
- Correlated_double_sampling wikiPageRevisionID "557400531".
- Correlated_double_sampling wikiPageWikiLink Category:Electricity.
- Correlated_double_sampling wikiPageWikiLink Category:Measurement.
- Correlated_double_sampling wikiPageWikiLink Dark-frame_subtraction.
- Correlated_double_sampling wikiPageWikiLink Electric_current.
- Correlated_double_sampling wikiPageWikiLink Switched_capacitor.
- Correlated_double_sampling wikiPageWikiLink Voltage.
- Correlated_double_sampling wikiPageWikiLinkText "Correlated double sampling".
- Correlated_double_sampling wikiPageWikiLinkText "correlated double sampling".
- Correlated_double_sampling hasPhotoCollection Correlated_double_sampling.
- Correlated_double_sampling wikiPageUsesTemplate Template:Cn.
- Correlated_double_sampling wikiPageUsesTemplate Template:Electronics-stub.
- Correlated_double_sampling subject Category:Electricity.
- Correlated_double_sampling subject Category:Measurement.
- Correlated_double_sampling hypernym Method.
- Correlated_double_sampling type Article.
- Correlated_double_sampling type Software.
- Correlated_double_sampling type Article.
- Correlated_double_sampling type Science.
- Correlated_double_sampling comment "Correlated double sampling (CDS) is a method to measure electrical values such as voltages or currents that allows removing an undesired offset. It is used often when measuring sensor outputs. The output of the sensor is measured twice: once in a known condition and once in an unknown condition.".
- Correlated_double_sampling label "Correlated double sampling".
- Correlated_double_sampling sameAs Muestreo_doble_correlacionado.
- Correlated_double_sampling sameAs m.04ygfwn.
- Correlated_double_sampling sameAs Q5172837.
- Correlated_double_sampling sameAs Q5172837.
- Correlated_double_sampling wasDerivedFrom Correlated_double_sampling?oldid=557400531.
- Correlated_double_sampling isPrimaryTopicOf Correlated_double_sampling.