Matches in DBpedia 2015-10 for { <http://dbpedia.org/resource/Blocked_rotor_test> ?p ?o }
Showing triples 1 to 36 of
36
with 100 triples per page.
- Blocked_rotor_test abstract "A blocked rotor test is conducted on an induction motor. It is also known as short circuit test, locked rotor test or stalled torque test. From this test, short circuit current at normal voltage, power factor on short circuit, total leakage reactance, and starting torque of the motor can be found. The test is conducted at low voltage because if the applied voltage was normal voltage then the current through the stator windings would be high enough to overheat the windings and damage them. The blocked rotor torque test is not performed on wound-rotor motors because the starting torque can be varied as desired. However, a blocked rotor current test is conducted on squirrel cage rotor motors.".
- Blocked_rotor_test wikiPageID "36263363".
- Blocked_rotor_test wikiPageLength "5701".
- Blocked_rotor_test wikiPageOutDegree "13".
- Blocked_rotor_test wikiPageRevisionID "676493589".
- Blocked_rotor_test wikiPageWikiLink Category:Electrical_circuits.
- Blocked_rotor_test wikiPageWikiLink Circle_diagram.
- Blocked_rotor_test wikiPageWikiLink Electrical_reactance.
- Blocked_rotor_test wikiPageWikiLink Full_load_current.
- Blocked_rotor_test wikiPageWikiLink Induction_motor.
- Blocked_rotor_test wikiPageWikiLink Inrush_current.
- Blocked_rotor_test wikiPageWikiLink Open-circuit_test.
- Blocked_rotor_test wikiPageWikiLink Open_circuit_test.
- Blocked_rotor_test wikiPageWikiLink Power_factor.
- Blocked_rotor_test wikiPageWikiLink Rotor_(electric).
- Blocked_rotor_test wikiPageWikiLink Short-circuit_test.
- Blocked_rotor_test wikiPageWikiLink Short_circuit.
- Blocked_rotor_test wikiPageWikiLink Short_circuit_current.
- Blocked_rotor_test wikiPageWikiLink Short_circuit_test.
- Blocked_rotor_test wikiPageWikiLink Slip_(motors).
- Blocked_rotor_test wikiPageWikiLink Torque.
- Blocked_rotor_test wikiPageWikiLink Voltage.
- Blocked_rotor_test wikiPageWikiLinkText "Blocked rotor test".
- Blocked_rotor_test wikiPageWikiLinkText "blocked rotor".
- Blocked_rotor_test hasPhotoCollection Blocked_rotor_test.
- Blocked_rotor_test wikiPageUsesTemplate Template:Reflist.
- Blocked_rotor_test subject Category:Electrical_circuits.
- Blocked_rotor_test type Article.
- Blocked_rotor_test type Article.
- Blocked_rotor_test comment "A blocked rotor test is conducted on an induction motor. It is also known as short circuit test, locked rotor test or stalled torque test. From this test, short circuit current at normal voltage, power factor on short circuit, total leakage reactance, and starting torque of the motor can be found. The test is conducted at low voltage because if the applied voltage was normal voltage then the current through the stator windings would be high enough to overheat the windings and damage them.".
- Blocked_rotor_test label "Blocked rotor test".
- Blocked_rotor_test sameAs m.0k2ldfr.
- Blocked_rotor_test sameAs Q4927255.
- Blocked_rotor_test sameAs Q4927255.
- Blocked_rotor_test wasDerivedFrom Blocked_rotor_test?oldid=676493589.
- Blocked_rotor_test isPrimaryTopicOf Blocked_rotor_test.